Soil Temperature & Humidity Sensor

About the product

The MP‑508C Soil Temperature & Humidity Sensor measures soil moisture and soil temperature at the same time. It helps growers understand how much water is available in the soil and how warm the root zone is — both are essential for healthy plant growth.

The sensor can be inserted into the soil for quick measurements or permanently installed for long‑term monitoring. Its stainless‑steel probe and sealed housing make it suitable for greenhouses, outdoor fields, and automated irrigation systems.

Specification

Soil moisture range: 0–100% (volumetric)

Soil temperature range: –20 to +80 °C

Response time: <1 second

Accuracy:  – Temperature: ±0.5 °C  – Moisture: ±2% (0–50% range)

Output: RS485 (Modbus RTU)

Operating voltage: 12–24 V DC

Working current: ~20 mA

Power consumption: ≤0.3 W

Protection level: IP68

Cable length: 3 m (shielded, 4‑core)

Probe material: Stainless steel 316

Housing material: ABS

Measurement zone: Cylinder approx. 2.5 cm × 6 cm around the probe

Installation

Open

  1. Insert the sensor probe fully into the soil.

  2. Avoid shaking or twisting the sensor during insertion.

  3. Do not install the sensor where stones or hard objects may damage the probe.

  4. When removing the sensor, pull it out by the body, not the cable.

  5. After use, clean and dry the probe.

Installation tips

● Vertical installation provides an average reading over ~6 cm depth.

● Choose a location with uniform soil density.

● Avoid areas with roots, gravel, or air pockets.

● For long‑term monitoring, ensure stable soil contact around the probe.

Calibration

This sensor does not require user calibration for normal operation. It is factory‑calibrated and ready to use.

Photosynthetically Active Radiation Sensor

About the product

The RY‑CGH Photosynthetically Active Radiation (PAR) Sensor measures the amount of light available for plant photosynthesis in the 400–700 nm range. This is the part of sunlight plants use to grow, and monitoring it helps optimize lighting, shading, and greenhouse conditions.

The sensor works outdoors in all weather and can be connected to a data logger or controller.

Specification

Spectral range: 400–700 nm

Measurement range: 0–4000 µmol/m²·s

Sensitivity: 7–50 µV per µmol/m²·s

Response time: <1 s

Temperature influence: ≤0.05% per °C

Cosine correction: Accurate up to 80° light angle

Output options:  – 4–20 mA (RY‑CGH/S)  – RS485 Modbus RTU (RY‑CGH/485)

Operating conditions:  – Temperature: –40 to +65 °C  – Humidity: <90%

Cable length: 3 m

Weight: ~220 g

Installation

Open

  1. Mount the sensor horizontally so the top dome faces the sky.

  2. Ensure nothing shades the sensor — even small shadows affect readings.

  3. Keep the sensor clean; dust or water spots reduce accuracy.

  4. For outdoor use, install in a stable location away from reflective surfaces.

  5. Avoid tilting the sensor — correct readings require a level surface.

Calibration

The sensor is factory‑calibrated and does not require user calibration.

Recommended maintenance:

● Clean the optical surface regularly

● Check that the sensor remains level

● Inspect the cable for damage in outdoor installations

Illuminance Sensor

About the product

The RY‑G/W Illuminance Sensor measures light intensity (Lux) in greenhouses, grow rooms, and outdoor environments. It helps growers understand how much visible light plants receive, allowing better control of shading, supplemental lighting, and environmental conditions.

The sensor has a durable aluminum housing, is waterproof (IP65), and works reliably outdoors.

Specification

Measurement ranges (optional):  – 0–2,000 Lux  – 0–20,000 Lux  – 0–200,000 Lux

Wavelength: 400–700 nm (visible light)

Accuracy: ±3% or 1% F.S

Response time: 1 s

Output options:  – 4–20 mA (RY‑G/W/S)  – RS485 Modbus RTU (RY‑G/W/485)

Power supply: 12 V or 24 V DC

Working current:  – <35 mA (voltage/current versions)  – <20 mA (RS485 version)

Power consumption:  – <0.42 W (voltage/current)  – <0.24 W (RS485)

Operating temperature: –30 to +60 °C

Protection level: IP65

Cable length: 3 m

Weight: 220 g

Installation

Open

  1. Mount the sensor horizontally with the lens facing upward.

  2. Ensure no objects cast shadows on the sensor.

  3. Keep the optical surface clean for accurate readings.

  4. Install away from reflective surfaces (metal, glass).

  5. For outdoor use, ensure stable mounting and proper sealing.

Calibration

The sensor is factory‑calibrated and does not require user calibration.

Recommended maintenance:

● Clean the lens regularly

● Ensure the sensor remains level

● Inspect cable and connectors periodically

Photoelectric Direct‑Reading Water Meter

About the product

The CC‑FL‑120W is a photoelectric direct‑reading water meter that reads the digit wheel electronically with zero reading error. Unlike pulse‑based meters, it directly detects the wheel position, ensuring fully accurate consumption data.

The meter uses a dry‑type rotary vane mechanism, offering high measurement accuracy, long service life, and stable operation. It is designed for smart metering systems and can integrate with remote monitoring platforms.

Specification

Model: CC‑FL‑120W

Power supply: 12–24 V DC

Interfaces: RS‑485 or M‑Bus

Operating current:  – M‑Bus: ≤10 mA (reading), ≤1.5 mA (static)  – RS‑485: ≤5 mA (reading), ≤1 mA (static)

Operating environment:  – Water temperature: 0.1–45 °C  – Humidity: 0–95% RH

Storage temperature: –25 to +65 °C

Max water pressure: 1 MPa

Max pressure loss: 0.063 MPa

Communication speed: 1200 / 2400 / 4800 / 9600 bps

Communication protocols: DL/T645, CJ/T188, internal or customer‑specified

Max communication distance: 300 m

Protection: IP68

ESD protection: >10 kV

Installation

Open

  1. Choose the meter size based on expected flow.

  2. Install the meter horizontally with the numbers facing upward.

  3. Ensure the arrow on the meter matches the water flow direction.

  4. Avoid locations with direct sunlight, freezing, moisture, or flooding.

  5. Flush new pipes before installation to remove debris.

  6. Use proper connectors — do not force or twist the meter body.

  7. Install valves before and after the meter for easy maintenance.

  8. Protect the meter from pipe stress; use a bracket if needed.

  9. During freezing periods, insulate the meter and pipes.

Calibration

The sensor is factory‑calibrated and does not require user calibration.

Temperature & Humidity Sensor

About the product

The RY‑WS301 is a compact, pen‑type sensor designed to measure air temperature and humidity in indoor and outdoor environments. It provides fast response, high accuracy, and stable long‑term performance. The sensor includes a protective filter tube that improves waterproofing and dust resistance, making it suitable for harsh or high‑humidity conditions.

Specification

Temperature range:  – Analog version: –40 to +60 °C  – RS485 version: –40 to +85 °C

Humidity range: 0–100% RH

Accuracy:  – Temperature: ±0.3 °C (typical @25 °C)  – Humidity: ±3% RH (10–80% RH @25 °C)

Response time: <15 s

Output: RS485 (Modbus RTU)

Power supply: 9–24 V DC

Working current: <20 mA @12 V

Consumption: <0.2 W

Operating temperature: –40 to +85 °C

Storage: –40 to +85 °C (non‑condensing)

Protection level: IP65

Cable length: 3 m (customizable)

Weight: <100 g

Installation

Open

  1. Install the sensor in a location with good air circulation.

  2. Avoid placing it near heat sources, direct sunlight, or ventilation outlets.

  3. For outdoor use, place the sensor inside a radiation shield (light‑shutter box).

  4. Ensure the filter tube remains clean and unobstructed.

  5. Mount the sensor vertically for best airflow.

Calibration

The sensor is factory‑calibrated and does not require user calibration.

Recommended maintenance:

● Clean the filter tube periodically

● Avoid exposure to corrosive gases

● Ensure the cable and connectors remain dry

Pressure Water Level Gauge

About the product

The RY‑CWYW/485 is a fully sealed, stainless‑steel pressure‑based water level and temperature sensor. It is designed for wells, tanks, rivers, industrial processes, hydrology, mining, and water‑management systems.

The sensor is drop‑in (submersible), highly stable, and supports long‑distance RS485 communication.

Specification

Measurement

Water level range: 0–10 m to 0–200 m (depending on model)

Accuracy: ±0.1% FS (0.2% / 0.5% optional)

Long‑term stability: <0.1% FS/year

Overload capacity: 5× FS

Temperature accuracy: ±0.2 °C (0–70 °C)

Temperature resolution: 0.01 °C

Environmental

Operating temperature: –10 to +80 °C

Compensated temperature: 0–50 °C

Storage temperature: –40 to +125 °C

Protection: IP68

Insulation: 100 MΩ @ 50 V

Electrical

Power supply: 9–30 V DC

Interface: RS485 (Modbus RTU)

Load capacity: up to 128 devices

Protections: reverse polarity, overvoltage, surge, EMI

Construction

Housing: Stainless steel 316L

Cable: PVC or polyurethane, with air‑guide tube

Cable diameter: 7.6 mm

Cable length: customizable

Installation

Open

  1. Lower the sensor into the well, tank, or water column using the cable.

  2. The cable includes a steel reinforcement wire — attach this wire securely so the weight is supported by the steel, not the electrical cable.

  3. Protect the cable connector at the wellhead to avoid blocking the air‑guide tube.

  4. Ensure the cable is not bent sharply or crushed.

  5. For absolute‑pressure versions, the air tube is not present.

Calibration

The sensor is factory‑calibrated and normally does not require adjustment.

Users may adjust: ● Zero offset (mm) ● Liquid density (kg/m³)

CO₂ Sensor

About the product

The RY‑VS09 CO₂ sensor measures carbon dioxide concentration in indoor and outdoor environments. It uses a high‑quality NDIR CO₂ probe imported from Sweden, providing stable readings, strong antistatic performance, and reliable long‑term operation.

The sensor is suitable for greenhouses, grow rooms, fresh‑air systems, storage facilities, and environmental monitoring.

Specification

Measurement principle: NDIR

Range: 0–5000 ppm

Accuracy: ±70 ppm ±3% of reading (after ABC stabilization)

Power supply: 12 V DC

Current consumption:  – RS485: <35 mA  – 4–20 mA: <55 mA

Power consumption:  – RS485: <0.42 W  – Current output: <0.66 W

Outputs:  – 4–20 mA (RY‑VS09)  – RS485 Modbus RTU (RY‑VS09/485)

Cable length: 1.5 m (current), 3 m (RS485)

Max cable distance:  – Current: 200 m  – RS485: 100 m

Operating temperature: 0–50 °C

Humidity: 0–100% RH (powered)

Preheat time: <1 min

Ingress protection: IP65

Weight: ~200 g

Housing size: 140 × 30 mm

Installation

Open

  1. Install the sensor indoors or outdoors in a location with good airflow.

  2. Keep it away from high‑power electrical equipment to avoid interference.

  3. Use the included U‑clip to mount the sensor on a wall or bracket.

  4. After installation, verify that data collection works normally.

  5. If readings are incorrect, check cable connections.

Calibration

The sensor uses ABC (Automatic Baseline Correction) and does not require manual calibration in normal environments.

Recommended maintenance:

● Keep the housing clean

● Avoid exposure to corrosive gases

● Ensure cables remain dry and undamaged

Compact Weather Station

About the product

The XF700A is a seven‑in‑one compact weather station that continuously monitors key outdoor environmental parameters. It integrates temperature, humidity, wind speed, wind direction, air pressure, rainfall, and light intensity into one device, providing real‑time data through a digital interface (RS485 Modbus RTU).

The station has no moving parts, is easy to install, and is designed for long‑term outdoor use.

Specification

Measured parameters

ParameterRangeAccuracyResolutionSampling
Air temperature–40 to +85 °C±0.3 °C @25 °C0.01 °C1 Hz
Air humidity0–100% RH±3% RH0.01% RH1 Hz
Wind speed0–60 m/s (75 m/s optional)±(0.3 + 0.03V) m/s0.01 m/s4 Hz
Wind direction0–359.9°±3° (<10 m/s)0.1°4 Hz
Air pressure500–1100 hPa±0.5 hPa0.1 hPa1 Hz
Rainfall0–200 mm/h0.01 mm1 Hz
Illuminance0–200 kLux±3% or 1% FS10 Lux1 Hz

General

Operating temperature: –40 to +80 °C

Output: RS485 Modbus RTU (SDI‑12 optional)

Power supply: 9–30 V DC

Protection: IP65

Cable: 3 m (10 m optional)

Mounting: Sleeve‑type (flange or bent‑plate optional)

Optional features: GPS, electronic compass, heating, CAN, ASCII, NMEA, 4G module

Wiring

The station uses a standard RS485 communication interface.

Power: 9–30 V DC

Communication: RS485 A/B

Cable: 4‑core shielded, 3 m (optional 10 m)

Installation

Open

  1. Mount the weather station using the sleeve, flange, or bent‑plate bracket.

  2. Install the device in an open area with no obstructions for accurate wind and rainfall measurement.

  3. Ensure the radiation shield (temperature/humidity/pressure sensors) is unobstructed and ventilated.

  4. Avoid installing near heat sources, reflective surfaces, or strong electromagnetic interference.

  5. Secure the cable to prevent movement or strain.

Calibration

The XF700A is factory‑calibrated and does not require user calibration.

Optional adjustments (via Modbus):

● Rainfall accumulation time

● Magnetic declination (if compass installed)

● Device address

● Baud rate

Component Temperature Sensor

About the product

The RY‑WS12S is a compact, waterproof temperature sensor designed for surface temperature monitoring of components such as equipment housings, panels, pipes, and electronic modules.

It uses a high‑precision temperature probe and a stable sampling algorithm to provide accurate readings. The sensor supports RS485 Modbus RTU communication and includes protection against over‑voltage, over‑current, and reverse polarity.

It is suitable for OEM integration, automation systems, and industrial monitoring.

Specification

Measurement range: –50 to +120 °C

Resolution: 0.01 °C

Accuracy: ±0.3 °C

Output: RS485 (Modbus RTU)

Power supply: 7–15 V DC (24 V optional)

Power consumption: <15 mA @12 V

Probe: Stainless steel Ø6 × 30 mm

Probe cable: 1 m

Transmitter cable: 15 m

Transmitter size: 60 × 35 × 25 mm

Protection: Waterproof design

Communication: Modbus RTU (address, baud rate, correction adjustable)

Installation

Open

  1. Attach the stainless‑steel probe directly to the surface of the component you want to measure.

  2. Use the disc‑shaped probe design to ensure good contact with flat surfaces.

  3. Secure the transmitter box using screws or adhesive if needed.

  4. Avoid installing near strong electromagnetic sources.

  5. Ensure the cable is not bent sharply or under tension.

Calibration

The sensor is factory‑calibrated. If needed, you can adjust:

Temperature correction value (–10.0 to +10.0 °C)

Device address

Communication baud rate

These settings are changed through Modbus commands.

Photoelectric Direct‑Reading Water Meter

About the product

The CC‑FL‑120W is a photoelectric direct‑reading water meter that reads the digit wheel electronically, eliminating the reading errors common in pulse‑type meters. It is designed for remote metering systems and provides zero electromechanical conversion error, high accuracy, and long service life.

The meter uses a dry‑type rotary vane mechanism, ensuring stable measurement, low starting flow, and reliable operation. It supports multiple communication protocols and integrates easily into smart metering systems for water, electricity, and gas.

Specification

Model: CC‑FL‑120W

Power supply: 12–24 V DC

Interfaces: RS485 or M‑Bus

Operating current:  – M‑Bus: ≤10 mA (reading), ≤1.5 mA (static)  – RS485: ≤5 mA (reading), ≤1 mA (static)

Operating environment:  – Water temperature: 0.1–45 °C  – Humidity: 0–95% RH

Storage temperature: –25 to +65 °C

Max water pressure: 1 MPa

Max pressure loss: 0.063 MPa

Communication speed: 1200 / 2400 / 4800 / 9600 bps

Protocols: DL/T645, CJ/T188, internal, or custom

Max communication distance: 300 m

Protection: IP68

ESD protection: >10 kV

Fault protection: open‑circuit, short‑circuit, idle‑time protection

Flow performance

ModelDN (mm)Q4 (m³/h)Q3 (m³/h)Q2 (m³/h)Q1 (m³/h)
CC‑FL‑15153.1252.50.0500.030
CC‑FL‑20205.004.00.0800.050
CC‑FL‑25257.8756.30.1280.080
CC‑FL‑323212.510.00.200.125
CC‑FL‑40402016.00.3200.200

Accuracy zones: ● Low zone (Q1 → Q2): ±5% ● High zone (Q2 → Q4): ±2%

Dimensions

DNLength (mm)Width (mm)Height (mm)ThreadWeight (kg)Cable (m)
1516598104G1/4B~1.40.8
2019598106G1B~1.70.8
25225103112G1¼B~2.50.8
32230104117G1½B~2.70.8
40245124147G2B~4.80.8

Installation

Open

  1. Select the meter diameter based on expected flow.

  2. Install horizontally with the digit wheel facing upward.

  3. Ensure the arrow on the meter matches the water flow direction.

  4. Avoid direct sunlight, freezing, moisture, and flooding.

  5. Flush new pipes before installation to remove debris.

  6. Prevent hot‑water backflow if installed near a boiler.

  7. Use proper connectors — do not force or twist the meter body.

  8. Install valves before and after the meter for easy maintenance.

  9. Protect the meter from pipe stress; use a bracket if needed.

Soil Temperature Sensor

About the product

The RY‑DW01 is a stainless‑steel soil temperature sensor designed for agricultural monitoring, storage environments, scientific research, and IoT systems. It provides accurate temperature readings with fast response time and stable performance. The sensor is available in 4–20 mA or RS485 Modbus RTU versions.

It is compact, waterproof, easy to install, and cost‑effective for long‑term field deployment.

Specification

Measurement range: –20 to +80 °C  (optional: –40 to +120 °C)

Accuracy: ±0.3 °C

Resolution: 0.01 °C

Output:  – 4–20 mA  – RS485 Modbus RTU

Probe size: Ø6 × 150 mm

Cable length: 3 m

Housing: Stainless steel, fully sealed, waterproof, anti‑corrosion

Installation

Open

  1. Insert the stainless‑steel probe fully into the soil.

  2. Avoid bending or forcing the probe into hard soil or stones.

  3. Ensure the cable is not under tension.

  4. For long‑term installation, protect the cable from moisture and mechanical damage.

  5. Keep the probe clean after removal.

Calibration

The sensor is factory‑calibrated and does not require user calibration.